Physical Dimensions
 
Video
 
Excellent performance for a wide variety of applications in multiple industries
 
In many fields, a moisture analyzer is a necessary tool for quality control requirements. With the MOC63u, you can easily obtain accurate data. Simply place material on the pan and shut the cover. The MOC63u will start to measure. The MOC63u adapts to various materials and increases your work efficiency.
 
Features
 
Halogen heater
Long-life and high power halogen heater provides quick and accurate measurement.
The temperature can be changed from 50 degrees to 200 degree Celsius. You can check sample status from window while measurement.
 
Large pan size: 95mm dia
MOC63u has large pwn. (95mm diameter)
It can provide quick and accurate measurement to spread sample in thin layer on the pan.
 
 
Data management and easy operation
 
Built-in USB port
The measure results can be transferred by USB cable. If connect with PC by USB, needs USB driver.
Please download from here.
 
WindowsDirect
Send balance data to Excel or other Windows applications without installing additional data communication software. By combining standard Auto print functions with typical spreadsheet functions, even difficult applications can be easily automated.
You can create graphs easily with WindowsDirect and Excel. If you need templates, please download from here. (xls/69KB) Connection to Windows Vista and Windows7.
 
Easy operation using a simple keypad
Features easy-to-operate software and keypad layout. In addition, an automatic starting mode saves measurement time, increasing your work efficiency. Operation simply requires ‘putting material on the pan and shutting the cover’. Internal memory can save 10 measurement conditions and 100 results. Various measurement modes provide extra support.
 
Various measurement modes
   
Ending modes:  
   
Automatic ending mode
Automatically ends measurement when moisture loss over the previous 30 seconds becomes smaller than specified percentage.
 
Timed ending mode
Automatically ends measurement when the specified amount of time has elapsed.
 
Alternative drying modes:  
   
Rapid drying mode
First dries with the highest temperature for the specified period, then shifts to the specified temperature, shortening measurement time.
 
Slow drying mode
Gently heats samples that might solidify at the surface or samples that reduce under high temperature.
 
Step drying mode
Allows step-by-step change in drying conditions. This feature is useful when measuring samples that contain a large amount of water.
 
Starting mode:
   
Automatic starting mode  
Starts measurement immediately after closing the lid. It saves time in repeat measurements.  
 
Specifications
 
Capacity 60g
0.02g
Minimum readability 0.001g
0.01/0.1% (Selectable)
Repeatability 0.15% (2g)
0.05% (5g)
0.02% (10g)
Drying Heater Straight type halogen heater
Power 400W
Temperature range 50-200°C (1°C increments)
Setting (There is a time restriction when exceeding 180°C.)
Display LCD with backlight
Pan size 95mm dia
Dimension (W×D×H) mm 202 × 336 × 157
Weight 4kg
Operational temperature and humidity range 5 to 40°C, 85%RH or lower
Measurement modes Standard
(Easy start/Automatic end/Timed end)
Rapid drying
(Easy start/Automatic end/Timed end)
Slow drying
(Easy start/Automatic end/Timed end)
Step drying
(Easy start/Automatic end/Timed end)
Timer setting 1-120 minutes or continuous
(max 12 hours)
Interface RS-232C (9-pin connector) I/O port
  USB port
Measurement conditions data memory 10
Data memory 100
 
Optional accessories
 
Optional accessories Printer EP-80
Printer EP-90
In-use protection cover for display (5 pieces)
Aluminum sheet
Fiberglass sheet
Temperature calibration kit
Sample pan (SUS)
RS-232C cable
USB connection cable
Halogen heater for replacement
 
License information
This software is provided by Future Technology Devices International Limited “as is” and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. In no event shall Future Technology Devices International Limited be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however caused and on any theory of liability, whether in contract, strict liability, or tort (including negligence or otherwise) arising in any way out of the use of this software, even if advised of the possibility of such damage. FTDI drivers may be used only in conjunction with products based on FTDI parts. FTDI drivers may be distributed in any form as long as license information is not modified. If a custom vendor ID and/or product ID or description string are used, it is the responsibility of the product manufacturer to maintain any changes and subsequent WHQL re-certification as a result of making these changes.
 
 
Brochure
Instruction Manual
Flyer
Windows Direct
 
 
Enlarge
   
 

Products


ATX/ATY Series
AU Series
AUW-D Series
AW/AX/AY Series
BL Series
BW-K/BX-K Series
ELB Series
MOC-120H
TW/TWC Series
TX/TXB/TXC Series
UW/UX Series
  1    
 
 
 
 

Quick Links

 

News

 

Quick Contact

 
 
   
 
Follow us: